Please read and understand this catalog before purchasing the products. 

Please consult your OMRON representative if you have any questions or 

comments. Refer to Warranty and Application Considerations (page 21), 

and Safety Precautions (page 17).

Solid-state Timer with Valuable Multiple-time 

Ranges and Multiple-operating Modes

• Handles a wide range of applications through eight operating 

modes.

• With H3BA-N8H models, the output type can be switched 

between time-limit DPDT and time-limit SPDT + instantaneous 

SPDT using a selector.

• Setting rings (order separately) to enable consistent settings 

and to limit the setting range.

• Panel Covers (order separately) to enable various panel 

designs.

• CE marking.

UL, CSA and CCC certification, conforms to LR.

■ Broad Line-up of H3B@-N Series

Model Number Structure

■ Model Number Legend

1. Number of Pins/Output

None: 11-pin models/Time-limit DPDT

8H: 8-pin models/Time-limit SPDT and switchable SPDT (time-limit ↔ instantaneous)

Ordering Information

■ Basic Setting

Setting of Selector

The selectors can be turned clockwise and counterclockwise to 

select the desired time unit, time range, output type (only for H3BAN8H) or operating mode.

Each selector has a snap mechanism that secures the selector at a 

given position. Set the selector at a position at which it is secured. Do 

not set it midway between two securing positions or a malfunction 

could result from improper setting.

Selection of Operating Mode with H3BA-N Turn the operating mode selector with a screwdriver until the desired operating mode (A, B, B2, C, D, E, G, or J) appears in the display window located above the selector. Selection of Output Type with H3BA-N8H Turn the output type selector with a screwdriver until the desired output type (A or H) appears in the display window located above the selector. Selection of Time Unit and Time Range The desired time unit (sec, 10 s, min, 10 m, hrs, or 10 h) is displayed in the window below the time setting knob by turning the time unit selector located at the lower right corner of the front panel. A time range (1.2, 3, 12, or 30) is selected with the time range selector at the lower left corner of the front panel, and the selected time range appears (in the window at the lower right part) within the plastic frame of the time setting knob.

■ Using the Setting Ring

Setting a Specific Time

Mount the Panel Cover on the Timer, set the desired time with the 

time setting knob, and place Time Setting Ring A onto the time 

setting knob so that the time setting notch of Time Setting Ring A is 

in the center of the reset lock position of the Panel Cover.

Limiting the Setting Range

Example: To set a range of 10 and 20 s.

Mount the Panel Cover on the Timer, set the time setting knob to 10 s 

(the lower limit of the setting range), and place Time Setting Ring C 

onto the time setting knob so that the stopper of Time Setting Ring C 

is on the right edge of the reset lock position of the Panel cover. Next, 

set the time setting knob to 20 s (the upper limit of the setting range), 

place Time Setting Ring B onto the time setting knob so that the 

stopper of Time Setting Ring B is on the left edge of the reset lock 

position of the Panel Cover.

Read and Understand this Catalog

Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have 

any questions or comments. 

Warranty and Limitations of Liability

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year 

(or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 

MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 

ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 

THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 

IMPLIED. 

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS 

OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 

CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. 

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. 

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 

PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 

INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 

MODIFICATION OR REPAIR. 

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the 

product in the customer’s application or use of the product.

Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 

be used. 

Know and observe all prohibitions of use applicable to this product.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 

ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 

PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 

SYSTEM.

PROGRAMMABLE PRODUCTS 

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS 

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 

your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS 

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA 

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a

warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application 

requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability