Piezoelectric Pressure

Transducer

Type CP 104

CHARACTERISTICS

• High-temperature capability -196°C to +400°C

• Acceleration compensated

• Operational in primary circuit of ABWR

• Proven reliability

• Will meet IEEE 323-1974

FEATURES

– Internal case insulation

– VC2 type crystal element

– Frequency response:

2 Hz to 6000 Hz

– Sensitivity

190 pC/bar

WEIGHT: 150 g

DESCRIPTION

The use of VC2 type single crystal material in the CP

104 compression mode dynamic pressure transducer

provides an extremely stable instrument.

The transducer is designed for long-term monitoring

or development testing.

The CP 104 pressure transducer may be operated with

either softline or hardline cables depending on the required temperature.

Input power requirements : None

Signal transmission : 2 pole system insulated from

casing, charge output

Signal processing : Charge converter

OPERATING (at 23 °C ± 5°C)

Sensitivity (at 2 Hz) : 190 pC/bar nominal

Dynamic measuring range

(random) : 0.00005 bar to 20 bar nominal

Overload capacity (spikes) : Up to 100 bar

Linearity : ±1% over dynamic measuring range

Acceleration sensitivity : ≤0,1 pC/g (≤0.0005 bar/g)

Resonant frequency : >30 kHz

Frequency response : 2 to 6000 Hz ±5% (lower cutoff frequency is determined by

the electronics used)

Internal insulation resist. : Min. 109 Ω (107 Ω at 300°C)

Capacitance : 85 pF nominal pole/pole

30 pF nominal pole/ground

ENVIRONMENTAL

Temperature range : -196°C to +350°C

Shock acceleration : <2000 g peak (half sine, 1 ms)

along sensitive axis

Corrosion, humidity : Inconel 600, hermetically

welded

Radiations

– Gamma flux : 1011 erg/g no effect

– Neutron flux : 1018 n/cm2 no effect

Mounting : 3 Allen screws M5

Fastening torque 10 Nm

CALIBRATION : Dynamic calibration at factory

at 1 bar peak and 2 Hz (23°C).

No subsequent calibration

necessary

Accessories :

– Connectors

– Cables

– Electronics

Ordering Information :

To order please specify:

– Type and designation : CP 104 Piezoelectric Pressure Transducer

– Ordering No. : 143-104-000-1

Due to the continual development of products, Vibro-Meter reserves the right to modify these specifications without forewarning